DATA LOGGERS

RST Instruments’ Data Loggers nodes and hubs collect and store data from a wide variety of geotechnical sensors and gauges, including vibrating wire and digital microelectromechanical systems (MEMS). They can automatically collect data from the sensor outputs and can be programmed to trigger an alarm when a reading reaches a pre-set critical threshold.

DT2011B VWP Default kPa Calculation Spreadsheet
Use this to convert raw data into the kPa and then the conversion of choice.
Tue, 17 May, 2022 at 4:06 PM
DT2011B VWP Default MPa Calculation Spreadsheet
Use this with the associated Cal Record to calculate the MPa then convert to output of choice. 
Tue, 17 May, 2022 at 4:07 PM
How to fix “Port Closed” error when a DT Logger is connected to DT Logger Host
Scenario: normally when the DT Logger is connect to the PC running DT Logger Host software, upon launching it will try to connect to the logger using curren...
Thu, 8 Jul, 2021 at 3:44 PM
DT Loggers (DT2011B, DT2055B, DT2040, etc.) setting consideration on application with Vibrating Wire Crack Meters.
When setting up the DT Loggers (DT2011B, DT2055B, DT2040, etc.) to read and display the Engineering Unit of Crack Meter value, e.g., in mm, there is an i...
Fri, 24 Jun, 2022 at 3:19 PM
How to setup a DT2011B Data Logger with a VW piezometer
Scenario: Customer needs to setup a RST DT2011B Data Logger with a RST VW Piezometer Solution: Follow the steps in the guide below to do the job. When ...
Thu, 8 Jul, 2021 at 3:48 PM
How to check the Xbee Frequencies of the DT Logger
How to check the Xbee Frequencies of the DT Logger Connect the Logger to DT Logger Host. Click on the Wireless Settings Click on RSTAR Settings ...
Wed, 6 Oct, 2021 at 3:29 PM
How to change Xbee Module from USA/Canada 900 MHz frequencies to Australia/Brasil Frequencies.
Use Putty Hyperterminal or YAT or Hyperterminal programs.     Check Serial Port, Add the ComPort # (e.g. COM15) and Baudrate = 921600 for USB Connectio...
Fri, 11 Mar, 2022 at 1:23 PM
How to Collect, Convert and View SAAV Instrument Data file by SAASuite ™ software
Collecting SAAV Extend Data Measurand’s SAAV Extend is a unique type of SAAV that can be lengthened in the field by adding segments to the top of a base ar...
Fri, 29 Oct, 2021 at 12:53 PM
How to Set up a DT2055B Data Logger with a 4 Coils VW Load Cell
On a VW Load cell, there are either 3, 4 or 6 gauges and a single thermistor connection. Each has to be set up as a separate channel in the data logger. In ...
Fri, 5 Nov, 2021 at 9:32 AM
How to setup a DT2055B Data Logger with a 3 Coils VW Load Cell
On a VW Load cell, there are between 3, 4 or 6 gauges and a thermistor connection. Each has to be set up as a separate channel in the data logger. In the ca...
Fri, 5 Nov, 2021 at 9:32 AM